CVE-2021-34764

MEDIUM CVSS 3.1: 6.1 EPSS 0.62%
Updated Aug 11, 2026
Cisco
Parameter Value
CVSS 6.1 (MEDIUM)
Affected Versions 6.5.0 — 6.7.0.3
Fixed In 6.4.0.13
Type CWE-601 (Open Redirect), CWE-79 (Cross-Site Scripting (XSS))
Vendor Cisco
Public PoC No

Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an attacker to execute a cross-site scripting (XSS) attack or an open redirect attack. For more information about these vulnerabilities, see the Details section of this advisory.

Attack Parameters

Attack Vector
Network
Can be exploited remotely
Attack Complexity
Low
Easy to exploit
Privileges Required
None
No privileges needed
User Interaction
Required
User action required

Impact Assessment

Confidentiality
Low
Partial data leak
Integrity
Low
Partial data modification
Availability
None
No disruption

CVSS Vector v3.1

Vulnerable Products 25

Configuration From (including) Up to (excluding)
Cisco Firepower_Management_Center_Virtual_Appliance
cpe:2.3:a:cisco:firepower_management_center_virtual_appliance:6.1.0:*:*:*:*:*:*:*
— —
Cisco Firepower_Management_Center_Virtual_Appliance
cpe:2.3:a:cisco:firepower_management_center_virtual_appliance:6.2.0:*:*:*:*:*:*:*
— —
Cisco Firepower_Management_Center_Virtual_Appliance
cpe:2.3:a:cisco:firepower_management_center_virtual_appliance:6.2.3:*:*:*:*:*:*:*
— —
Cisco Firepower_Management_Center_Virtual_Appliance
cpe:2.3:a:cisco:firepower_management_center_virtual_appliance:6.3.0:*:*:*:*:*:*:*
— —
Cisco Firepower_Management_Center_Virtual_Appliance
cpe:2.3:a:cisco:firepower_management_center_virtual_appliance:6.4.0:*:*:*:*:*:*:*
— —
Cisco Firepower_Management_Center_Virtual_Appliance
cpe:2.3:a:cisco:firepower_management_center_virtual_appliance:6.5.0:*:*:*:*:*:*:*
— —
Cisco Firepower_Management_Center_Virtual_Appliance
cpe:2.3:a:cisco:firepower_management_center_virtual_appliance:6.6.0:*:*:*:*:*:*:*
— —
Cisco Firepower_Management_Center_Virtual_Appliance
cpe:2.3:a:cisco:firepower_management_center_virtual_appliance:6.6.1:*:*:*:*:*:*:*
— —
Cisco Firepower_Management_Center_Virtual_Appliance
cpe:2.3:a:cisco:firepower_management_center_virtual_appliance:6.7.0:*:*:*:*:*:*:*
— —
Cisco Firepower_Management_Center_Virtual_Appliance
cpe:2.3:a:cisco:firepower_management_center_virtual_appliance:7.0.0:*:*:*:*:*:*:*
— —
Cisco Firepower_Management_Center_Virtual_Appliance
cpe:2.3:a:cisco:firepower_management_center_virtual_appliance:7.1.0:*:*:*:*:*:*:*
— —
Cisco Secure_Firewall_Threat_Defense
cpe:2.3:a:cisco:secure_firewall_threat_defense:*:*:*:*:*:*:*:*
— 6.4.0.13
Cisco Secure_Firewall_Threat_Defense
cpe:2.3:a:cisco:secure_firewall_threat_defense:*:*:*:*:*:*:*:*
6.5.0 6.6.5
Cisco Secure_Firewall_Threat_Defense
cpe:2.3:a:cisco:secure_firewall_threat_defense:*:*:*:*:*:*:*:*
6.7.0 6.7.0.3
Cisco Sourcefire_Defense_Center
cpe:2.3:a:cisco:sourcefire_defense_center:6.1.0:*:*:*:*:*:*:*
— —
Cisco Sourcefire_Defense_Center
cpe:2.3:a:cisco:sourcefire_defense_center:6.2.0:*:*:*:*:*:*:*
— —
Cisco Sourcefire_Defense_Center
cpe:2.3:a:cisco:sourcefire_defense_center:6.2.3:*:*:*:*:*:*:*
— —
Cisco Sourcefire_Defense_Center
cpe:2.3:a:cisco:sourcefire_defense_center:6.3.0:*:*:*:*:*:*:*
— —
Cisco Sourcefire_Defense_Center
cpe:2.3:a:cisco:sourcefire_defense_center:6.4.0:*:*:*:*:*:*:*
— —
Cisco Sourcefire_Defense_Center
cpe:2.3:a:cisco:sourcefire_defense_center:6.5.0:*:*:*:*:*:*:*
— —
Cisco Sourcefire_Defense_Center
cpe:2.3:a:cisco:sourcefire_defense_center:6.6.0:*:*:*:*:*:*:*
— —
Cisco Sourcefire_Defense_Center
cpe:2.3:a:cisco:sourcefire_defense_center:6.6.1:*:*:*:*:*:*:*
— —
Cisco Sourcefire_Defense_Center
cpe:2.3:a:cisco:sourcefire_defense_center:6.7.0:*:*:*:*:*:*:*
— —
Cisco Sourcefire_Defense_Center
cpe:2.3:a:cisco:sourcefire_defense_center:7.0.0:*:*:*:*:*:*:*
— —
Cisco Sourcefire_Defense_Center
cpe:2.3:a:cisco:sourcefire_defense_center:7.1.0:*:*:*:*:*:*:*
— —