CVE-2025-22961

HIGH CVSS 3.1: 8.0 EPSS 0.41%
Updated Mar 12, 2025
Parameter Value
CVSS 8.0 (HIGH)
Type CWE-200 (Information Exposure)
Public PoC No

A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access Control (CWE-284). Unauthenticated attackers can directly access sensitive database backup files (snapshot_users.db) via publicly exposed URLs (/logs/devcfg/snapshot/ and /logs/devcfg/user/). Exploiting this vulnerability allows retrieval of sensitive user data, including login credentials, potentially leading to full system compromise.

Attack Parameters

Attack Vector
Network
Can be exploited remotely
Attack Complexity
Low
Easy to exploit
Privileges Required
Low
Basic privileges needed
User Interaction
Required
User action required

Impact Assessment

Confidentiality
High
Complete data leak
Integrity
High
Complete data modification
Availability
High
Complete denial of service

CVSS Vector v3.1

Weakness Type (CWE)