CVE-2025-26793

CRITICAL CVSS 4.0: 10.0 EPSS 2.40%
Updated Feb 24, 2025
Parameter Value
CVSS 10.0 (CRITICAL)
Type CWE-1393 (Use of Default Password)
Public PoC No

The Web GUI configuration panel of Hirsch (formerly Identiv and Viscount) Enterphone MESH through 2024 ships with default credentials (username freedom, password viscount). The administrator is not prompted to change these credentials on initial configuration, and changing the credentials requires many steps. Attackers can use the credentials over the Internet via mesh.webadmin.MESHAdminServlet to gain access to dozens of Canadian and U.S. apartment buildings and obtain building residents' PII.

NOTE: the Supplier's perspective is that the "vulnerable systems are not following manufacturers' recommendations to change the default password."

Attack Parameters

Attack Vector
Network
Can be exploited remotely
Attack Complexity
Low
Easy to exploit
Attack Requirements
None
No additional conditions
Privileges Required
None
No privileges needed
User Interaction
None
No user interaction needed

Impact Assessment

Confidentiality
High
Complete data leak
Integrity
High
Complete data modification
Availability
None
No disruption

CVSS Vector v4.0