CVE-2025-30042

CRITICAL CVSS 4.0: 9.0 EPSS 0.02%
Updated Mar 02, 2026
Parameter Value
CVSS 9.0 (CRITICAL)
Type CWE-603
Public PoC No

The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key.

Attack Parameters

Attack Vector
Adjacent
Requires local network access
Attack Complexity
Low
Easy to exploit
Attack Requirements
Present
Additional conditions required
Privileges Required
None
No privileges needed
User Interaction
None
No user interaction needed

Impact Assessment

Confidentiality
High
Complete data leak
Integrity
High
Complete data modification
Availability
High
Complete denial of service

CVSS Vector v4.0

Weakness Type (CWE)