CVE-2025-40594

MEDIUM CVSS 4.0: 6.9 EPSS 0.21%
Updated Oct 24, 2026
Siemens
Parameter Value
CVSS 6.9 (MEDIUM)
Type CWE-269 (Improper Privilege Management)
Vendor Siemens
Public PoC No

A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions < V6.4 HF7), SINAMICS S210 V6.4 (All versions < V6.4 HF2). The affected devices allow a factory reset to be executed without the required privileges due to improper privilege management as well as manipulation of configuration data because of leaked privileges of previous sessions. This could allow an unauthorized attacker to escalate their privileges.

Attack Parameters

Attack Vector
Local
Requires local access
Attack Complexity
High
Difficult to exploit
Attack Requirements
Present
Additional conditions required
Privileges Required
None
No privileges needed
User Interaction
Active
User action required

Impact Assessment

Confidentiality
None
No data leak
Integrity
High
Complete data modification
Availability
Low
Partial disruption

CVSS Vector v4.0

Vulnerable Products 8

Configuration From (including) Up to (excluding)
Siemens Sinamics_G220_Firmware
cpe:2.3:o:siemens:sinamics_g220_firmware:6.4:-:*:*:*:*:*:*
— —
Siemens Sinamics_G220_Firmware
cpe:2.3:o:siemens:sinamics_g220_firmware:6.4:hf1:*:*:*:*:*:*
— —
Siemens Sinamics_G220
cpe:2.3:h:siemens:sinamics_g220:-:-:*:*:*:*:*:*
— —
Siemens Sinamics_S200_Firmware
cpe:2.3:o:siemens:sinamics_s200_firmware:6.4:*:*:*:*:*:*:*
— —
Siemens Sinamics_S200
cpe:2.3:h:siemens:sinamics_s200:-:*:*:*:*:*:*:*
— —
Siemens Sinamics_S210_Firmware
cpe:2.3:o:siemens:sinamics_s210_firmware:6.4:-:*:*:*:*:*:*
— —
Siemens Sinamics_S210_Firmware
cpe:2.3:o:siemens:sinamics_s210_firmware:6.4:hf1:*:*:*:*:*:*
— —
Siemens Sinamics_S210
cpe:2.3:h:siemens:sinamics_s210:-:-:*:*:*:*:*:*
— —