CVE-2025-40774

MEDIUM CVSS 4.0: 6.7 EPSS 0.14%
Updated Oct 24, 2026
Siemens
Parameter Value
CVSS 6.7 (MEDIUM)
Affected Versions before 3.00
Fixed In 3.00
Type CWE-257
Vendor Siemens
Public PoC No

A vulnerability has been identified in SiPass integrated (All versions < V3.0). Affected server applications store user passwords encrypted in its database. Decryption keys are accessible to users with administrative privileges, allowing them to recover passwords.

Successful exploitation of this vulnerability allows an attacker to obtain and use valid user passwords. This can lead to unauthorized access to user accounts, data breaches, and potential system compromise.

Attack Parameters

Attack Vector
Local
Requires local access
Attack Complexity
Low
Easy to exploit
Attack Requirements
None
No additional conditions
Privileges Required
High
Admin privileges needed
User Interaction
None
No user interaction needed

Impact Assessment

Confidentiality
High
Complete data leak
Integrity
None
No data modification
Availability
None
No disruption

CVSS Vector v4.0

Weakness Type (CWE)

Vulnerable Products 1

Configuration From (including) Up to (excluding)
Siemens Sipass_Integrated
cpe:2.3:a:siemens:sipass_integrated:*:*:*:*:*:*:*:*
— 3.00