CVE-2025-4596

MEDIUM CVSS 4.0: 5.3 EPSS 0.31%
Updated Oct 07, 2026
Asseco
Parameter Value
CVSS 5.3 (MEDIUM)
Fixed In 6.09.01.62
Type CWE-639 (Authorization Bypass)
Vendor Asseco
Public PoC No

Asseco ADMX system is used for processing medical records. It allows logged in users to access medical files belonging to other users through manipulation of GET arguments containing document IDs. This issue has been fixed in 6.09.01.62 version of ADMX.

Attack Parameters

Attack Vector
Network
Can be exploited remotely
Attack Complexity
Low
Easy to exploit
Attack Requirements
None
No additional conditions
Privileges Required
Low
Basic privileges needed
User Interaction
None
No user interaction needed

Impact Assessment

Confidentiality
Low
Partial data leak
Integrity
None
No data modification
Availability
None
No disruption

CVSS Vector v4.0

Weakness Type (CWE)