A reachable assertion vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.2, specifically within the Level Control cluster's periodic server tick logic. When a MoveToLevel command is sent and immediately followed by a write of OperationMode=2 (in the Pump Configuration and Control cluster), the server tick function violates the assertion `currentLevel < maxLevel`, resulting in a crash. This can be exploited remotely without authentication to cause denial of service.
Affected versions include 1.3 and 1.4 (commit ab3d5ae).
Attack Parameters
Impact Assessment
CVSS Vector v3.1
Weakness Type (CWE)
Vulnerable Products 2
| Configuration | From (including) | Up to (excluding) |
|---|---|---|
|
Csa-Iot Matter
cpe:2.3:a:csa-iot:matter:1.3.0.0:*:*:*:*:*:*:*
|
— | — |
|
Csa-Iot Matter
cpe:2.3:a:csa-iot:matter:1.4.0.0:*:*:*:*:*:*:*
|
— | — |