CVE-2026-107612

HIGH CVSS 3.1: 7.8 EPSS 0.10%
Updated Oct 09, 2026
Incorrect
Parameter Value
CVSS 7.8 (HIGH)
Affected Versions before 2.8.88
Type CWE-338, CWE-732 (Incorrect Permission Assignment)
Vendor Incorrect
Public PoC No

Incorrect permission assignment in GlavSoft TightVNC Server for Windows before 2.8.88 allows a local authenticated user to read or overwrite the inter-process communication handles used between the TightVNC service and its desktop server process. The named shared memory segment in the Global\ namespace that carries the pipe HANDLE values is created with a NULL DACL, and its name is derived from a time-seeded srand(time(0)) value that is predictable to one-second granularity. A low-privileged local process can open the mapping and tamper with the IPC channel of a service running as SYSTEM, potentially leading to disclosure of session data, privilege escalation, or denial of service.

Attack Parameters

Attack Vector
Local
Requires local access
Attack Complexity
Low
Easy to exploit
Privileges Required
Low
Basic privileges needed
User Interaction
None
No user interaction needed

Impact Assessment

Confidentiality
High
Complete data leak
Integrity
High
Complete data modification
Availability
High
Complete denial of service

CVSS Vector v3.1