CVE-2026-111215

HIGH CVSS 4.0: 8.6 EPSS 7.51%
Updated Nov 18, 2026
Pfsense
Parameter Value
CVSS 8.6 (HIGH)
Affected Versions before 2.9.0
Type CWE-78 (OS Command Injection)
Vendor Pfsense
Public PoC No

Netgate pfSense CE through 2.9.0 and Plus through 26.07 contains an OS command injection vulnerability that allows authenticated users to execute commands as root by supplying a crafted wireless parent interface name. Attackers with limited Wireless Edit or Interface Assignments privileges can submit values like ath0;<cmd> via interfaces_wireless_edit.php or interfaces_assign.php, which interface_wireless_clone() interpolates unescaped into an ifconfig shell command.

Attack Parameters

Attack Vector
Network
Can be exploited remotely
Attack Complexity
Low
Easy to exploit
Attack Requirements
None
No additional conditions
Privileges Required
High
Admin privileges needed
User Interaction
None
No user interaction needed

Impact Assessment

Confidentiality
High
Complete data leak
Integrity
High
Complete data modification
Availability
High
Complete denial of service

CVSS Vector v4.0

Weakness Type (CWE)

Vulnerable Products 1

Configuration From (including) Up to (excluding)
Pfsense Pfsense
cpe:2.3:a:pfsense:pfsense:*:*:*:*:community:*:*:*
— <= 2.9.0