CVE-2026-119746

HIGH CVSS 4.0: 8.2 EPSS 0.54%
Updated Nov 13, 2026
ProSoft
Parameter Value
CVSS 8.2 (HIGH)
Fixed In 1.14.158
Type CWE-307, CWE-602
Vendor ProSoft
Public PoC No

ProSoft Technology ICX35 devices (X35-HWC-A and ICX35-HWC-E) contain a login lockout bypass in the integrated module web page. The account lockout mechanism that restricts repeated failed authentication attempts is enforced in client-side JavaScript, so a remote attacker can reset the lockout and continue submitting password guesses by deleting the relevant browser cookies, defeating the brute-force protection. This vulnerability has been addressed in version 1.14.158.

Attack Parameters

Attack Vector
Network
Can be exploited remotely
Attack Complexity
High
Difficult to exploit
Attack Requirements
None
No additional conditions
Privileges Required
None
No privileges needed
User Interaction
None
No user interaction needed

Impact Assessment

Confidentiality
High
Complete data leak
Integrity
None
No data modification
Availability
None
No disruption

CVSS Vector v4.0

Weakness Type (CWE)