CVE-2026-18186

HIGH CVSS 4.0: 7.1 EPSS 0.46%
Updated Oct 24, 2026
Asustor
Parameter Value
CVSS 7.1 (HIGH)
Affected Versions 4.1.0.rhu2 — 5.1.4.rjv2
Fixed In 5.1.4.rjv2
Type CWE-134 (Use of Externally-Controlled Format String)
Vendor Asustor
Public PoC No

A stored format string vulnerability was found in the FTP Backup on the ADM. The vulnerability occurs because user-controlled backup configuration data may be written into a task log and later processed through an unsafe format string operation. An authenticated attacker can exploit this issue to disclose memory information or cause denial of service of the affected CGI process.

Affected products and versions include: from ADM 4.1.0 through ADM 4.3.3.RUN1 as well as from ADM 5.0.0 through ADM 5.1.3.RI81.

Attack Parameters

Attack Vector
Network
Can be exploited remotely
Attack Complexity
Low
Easy to exploit
Attack Requirements
None
No additional conditions
Privileges Required
Low
Basic privileges needed
User Interaction
None
No user interaction needed

Impact Assessment

Confidentiality
Low
Partial data leak
Integrity
None
No data modification
Availability
High
Complete denial of service

CVSS Vector v4.0

Vulnerable Products 2

Configuration From (including) Up to (excluding)
Asustor Data_Master
cpe:2.3:o:asustor:data_master:*:*:*:*:*:*:*:*
4.1.0.rhu2 <= 4.3.3.run1
Asustor Data_Master
cpe:2.3:o:asustor:data_master:*:*:*:*:*:*:*:*
5.0.0.ra82 5.1.4.rjv2