CVE-2026-25599

MEDIUM CVSS 3.1: 6.3 EPSS 0.11%
Updated Jul 22, 2026
Parameter Value
CVSS 6.3 (MEDIUM)
Type CWE-306 (Missing Authentication for Critical Function), CWE-319 (Cleartext Transmission), CWE-79 (Cross-Site Scripting (XSS))
Public PoC No

Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.

Attack Parameters

Attack Vector
Network
Can be exploited remotely
Attack Complexity
Low
Easy to exploit
Privileges Required
None
No privileges needed
User Interaction
Required
User action required

Impact Assessment

Confidentiality
Low
Partial data leak
Integrity
Low
Partial data modification
Availability
Low
Partial disruption

CVSS Vector v3.1