CVE-2026-37224

HIGH CVSS 3.1: 7.5 EPSS 0.43%
Updated Jul 22, 2026
FlexRIC
Parameter Value
CVSS 7.5 (HIGH)
Type CWE-617
Vendor FlexRIC
Public PoC No

FlexRIC v2.0.0 crashes when receiving a duplicate E2_SETUP_REQUEST from the same or spoofed E2 Node. The iApp registry enforces node ID uniqueness via assert() rather than graceful rejection. A remote unauthenticated attacker can crash the iApp process (port 36421) by sending two E2_SETUP_REQUESTs with the same E2 node configuration, triggering SIGABRT.

Attack Parameters

Attack Vector
Network
Can be exploited remotely
Attack Complexity
Low
Easy to exploit
Privileges Required
None
No privileges needed
User Interaction
None
No user interaction needed

Impact Assessment

Confidentiality
None
No data leak
Integrity
None
No data modification
Availability
High
Complete denial of service

CVSS Vector v3.1

Weakness Type (CWE)