CVE-2026-4638

HIGH CVSS 4.0: 7.1 EPSS 0.27%
Updated Sep 24, 2026
PRTG
Parameter Value
CVSS 7.1 (HIGH)
Affected Versions before 26.2.120.1449
Type CWE-209 (Information Exposure Through Error Message)
Vendor PRTG
Public PoC No

PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter.  Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.

Attack Parameters

Attack Vector
Network
Can be exploited remotely
Attack Complexity
Low
Easy to exploit
Attack Requirements
None
No additional conditions
Privileges Required
Low
Basic privileges needed
User Interaction
None
No user interaction needed

Impact Assessment

Confidentiality
High
Complete data leak
Integrity
None
No data modification
Availability
None
No disruption

CVSS Vector v4.0