CVE-2026-50577

HIGH CVSS 3.1: 7.4 EPSS 0.51%
Updated Oct 23, 2026
Fbeta-Gmbh
Parameter Value
CVSS 7.4 (HIGH)
Fixed In 1.3.0
Type CWE-323
Vendor Fbeta-Gmbh
Public PoC No

ePA 3.x Integration implements the authorization workflow and writes Medical Information Objects to Germany's electronic patient record. Prior to 1.3.0, ePA 3.x Integration leaves request_counter unchanged in app/vau/VAUProtokoll.py while constructing VAU messages. The frozen client request counter causes the server side to reuse AES-GCM nonce and key combinations across responses.

A network attacker who collects repeated ciphertexts can recover the XOR of plaintexts and use predictable inner HTTP headers and JSON fields to recover sensitive data, including patient health records. Repeated nonces can also enable recovery of the GHASH authentication key through the Joux forbidden attack, allowing forged AES-GCM messages and injection of malicious responses. The response-counter check also fails to maintain last_response_counter, weakening replay and ordering validation.

This issue is fixed in version 1.3.0.

Attack Parameters

Attack Vector
Network
Can be exploited remotely
Attack Complexity
High
Difficult to exploit
Privileges Required
None
No privileges needed
User Interaction
None
No user interaction needed

Impact Assessment

Confidentiality
High
Complete data leak
Integrity
High
Complete data modification
Availability
None
No disruption

CVSS Vector v3.1

Weakness Type (CWE)

Vulnerable Products

fbeta-gmbh:epa3-service-opensource