CVE-2026-78224

HIGH CVSS 4.0: 8.8 EPSS 0.44%
Updated Sep 11, 2026
Nextgen Healthcare
Parameter Value
CVSS 8.8 (HIGH)
Type CWE-611
Vendor Nextgen Healthcare
Public PoC No

The XSLT Transformer Step builds a bare TransformerFactory without the proper security options set, so XXE injection can allow data exfiltration and denial-of-service attacks.

Attack Parameters

Attack Vector
Network
Can be exploited remotely
Attack Complexity
Low
Easy to exploit
Attack Requirements
None
No additional conditions
Privileges Required
None
No privileges needed
User Interaction
None
No user interaction needed

Impact Assessment

Confidentiality
High
Complete data leak
Integrity
None
No data modification
Availability
Low
Partial disruption

CVSS Vector v4.0

Weakness Type (CWE)

Vulnerable Products

nextgen healthcare:mirth connect