CVE-2026-87662

HIGH CVSS 4.0: 7.0 EPSS 0.25%
Updated Oct 14, 2026
Broadcom
Parameter Value
CVSS 7.0 (HIGH)
Affected Versions 10.0.0 — 9.2.2d
Fixed In 9.2.2d
Type CWE-78 (OS Command Injection)
Vendor Broadcom
Public PoC No

Brocade Fabric versions before 9.2.2d and 10.0.0 through 10.0.0a1 handling of specific download protocols utilizes unsanitized parameter strings. When processing upgrade requests, parameters are converted into system command strings and executed through a system shell interface. Because control characters and shell metacharacters in fields like the host or file path are not stripped or sanitized, an attacker can execute arbitrary shell commands with the firmware management daemon's elevated privileges.

Attack Parameters

Attack Vector
Local
Requires local access
Attack Complexity
Low
Easy to exploit
Attack Requirements
None
No additional conditions
Privileges Required
High
Admin privileges needed
User Interaction
Passive
Minimal interaction

Impact Assessment

Confidentiality
High
Complete data leak
Integrity
High
Complete data modification
Availability
High
Complete denial of service

CVSS Vector v4.0

Weakness Type (CWE)

Vulnerable Products 2

Configuration From (including) Up to (excluding)
Broadcom Fabric_Operating_System
cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*
— 9.2.2d
Broadcom Fabric_Operating_System
cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*
10.0.0 10.0.1