Ad

CVE-2026-80146

CRITICAL CVSS 4.0: 9,4 EPSS 0.85%
Обновлено 26 сентября 2026
Lantronix
Параметр Значение
CVSS 9,4 (CRITICAL)
Тип уязвимости CWE-121 (Переполнение буфера в стеке)
Поставщик Lantronix
Публичный эксплойт Нет

Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom read command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices.

Характеристики атаки

Способ атаки
По сети
Атака возможна удалённо
Сложность
Низкая
Легко эксплуатировать
Условия для атаки
Не требуются
Нет дополнительных условий
Нужны права
Низкие
Нужны базовые права
Участие пользователя
Не требуется
Не нужно действие пользователя

Последствия

Конфиденциальность
Высокое
Полная утечка данных
Целостность
Высокое
Полная модификация данных
Доступность
Высокое
Полный отказ в обслуживании

Строка CVSS v4.0